lnLokota

TDS Ezali Nini Na Ba Tours De Refroidissement

Jul 06, 2026

Botika message .

Applicable Industries and Application Advantages of Closed Cooling Towers

 
 

TDS mpe ba Tours de Refroidissement oyo ekangami

TDS ezali mokuse ya Total Dissolved Solids, oyo elakisi masse totale ya ba substances inorganiques mpe organiques nionso oyo ekoki ko soluble oyo epanzani na mayi, emesami na mg/L to ppm.

Na mayi oyo ezali kotambola na tour de refroidissement, TDS ezali mingi mingi na ba ions calcium, ba ions magnésium, ba ions chlorure, ba ions sulfate, silicate mpemungwa mosusu ya minerais, bakisa mpe biloko oyo ebebisaka biloko oyo bizali na bomoi oyo epanzani oyo mputulu ya mopɛpɛ mpe gaze oyo euti na baizini ememaka.

 
1396

bandimi oyo bazali kosala mosala

 
15+

bambula ya eksperiansi

 
125+

makambo & mikakatano

 
12

balakisi ya mayele

 

Valeur TDS ezali indice ya contrôle ya qualité ya mayi ya moboko ya fonctionnement ya tour de refroidissement, oyo e déterminer directement ba risques ya échelle, corrosion pe reproduction microbiennes ya ouverte peba systèmes ya refroidissement semi-clos, mpe boyangeli ya TDS oyo ebongi te ekosala makama minene oyo ebombami mpo na efficacité ya refroidissement mpe na vie ya service ya équipement.

 

 

What Coil Material to Use for Closed-Circuit Cooling Towers for Air Compressor Cooling?Mecanisme ya formation ya TDS ya likolo na mayi ya tour de refroidissement ezali na cycle ya concentration continue ya mayi.

 

Ba tours ya refroidissement etie motema na évaporation ya mayi mpo na kolongola molunge, alors que mayi ya peto e vaporiser na mopepe, mpe ba substances minerais nionso oyo epanzani ekoki ko évaporer te mpe kotikala na mayi oyo ezali ko circuler continuellement.

 

Lokola mai ezali kobungisa ntango nyonso, motángo ya biloko ya makasi oyo ekoki kopɔla ezali se komata, mpemotuya ya TDS emati na ndenge ya linéaire na tango ya opération.

 

Ata soki izini yango etondisaka mai ya sika ya robinet to mai ya libulu mikolo nyonso, mai ya sika ekomema biloko ya sika ya mabanga ya ntalo, mpe yango ekosala ete TDS ekóma nokinoki.

 

 

Mpo na ba tours ya refroidissement ya polele oyo ezali na mopepe, mputulu ya libanda, brume ya acide industriel, brume ya mungwa mpe bosoto ya biologique ekopanzana ntango nyonso na mayi oyo ezali kotambola, oyo ekopusama lisusu likoloniveau ya TDS.

 

 

Do Closed Cooling Towers Need Frequent Water Replenishment During Operation?Na ba izini oyo ezali pembenipembeni ya mbu, ba ions chlorure oyo ezali na kati ya mpela ya mungwa ebakisaka mpenza TDS; na ba parcs ya mabanga ya ntalo mpe ya chimique, ba sulfates mpe ba solides dissous na ba métaux lourds esalaka que TDS eleka norme noki.

 

Ba systèmes ya refroidissement fermé ezali na vitesse ya bomati ya TDS ya se po milieu ya kati ezali isolé na mopepe, nzokande fonctionnement ya tango molayi-pe remplissage ya mayi mbala na mbala ekosala kaka na concentration ya TDS malembe.

 

 

TDS eleki ndelo ememaka makama misato ya minene ya koboma na tour ya refroidissement mpe na bisaleli ya kosunga. Likama ya liboso ezali kokita makasi. Mungwa ya calcium mpe magnésium ezali biloko ya ntina mingi oyo esalaka TDS. Tango TDS eleki seuil oyo etiamaki, limite ya solubilité ya carbonate de calcium, silicat de magnésium na ba précipités misusu ebukanaka, mpe échelle cristalline ekangamaka na likolo ya ba échangeurs ya chaleur, ba tuyaux ya bobines mpe ba tubes ya condensateur.

 

 

Why Are Closed Circuit Cooling Towers So Popular?

Échelle ezali na conductivité thermique très faible, oyo ekitisaka mingi efficacité ya échange ya chaleur. Tango épaisseur ya échelle ekomi na 0,3mm, capacité ya dissipation ya chaleur ya ba équipements ya refroidissement ekiti na plus de 20%, ememaka na surchauffage ya équipement, arrêt ya production pe bomati ya consommation ya puissance ya ba ventilateurs na ba pompes ya mayi.

 

 

Kosala pickling manuel mpe ko déscaler mécanique esengaka temps ya arrêt ya molayi mpe ba frais ya entretien ya likolo, mpekosala pickling mbala na mbalaekobebisa bifelo ya ba tuyaux ya bibende mpe ekosala ete makama ya fuite ebombama.

 

 

Likama ya mibale ezali bongo kopɔla ya bibende nokinoki. Ba ions chlorure na sulfate na TDS ezali ba médias corrosifs ya makasi. Mai oyo ezali kotambola na TDS ya likolo esalaka environnement ya corrosion électrochimique na ba tuyaux ya acier carbone, ba bobines ya acier inoxydable mpe ba boîtiers ya pompe.

 

 

 

Disadvantages Of Closed-Loop Cooling SystemsBa ions chlorure eko kota na film passif na surface ya métal, ekosala que corrosion ya pitting mpe perforation ya ba bobines d’échange ya chaleur, surtout ba tuyaux duplex ya acier inoxydable mpe ya cuivre na ba tours de refroidissement fermé.

 

Na makambo ya makasi, fuite ya milieu de refroidissement ekobebisa ba équipements ya production lokola ba lignes ya production ya piles na ba réacteurs pharmaceutiques. TDS ya likolo e intensifier pe corrosion galvanique entre ba matériaux métalliques différents na système ya pipeline, ezo réduire vie ya service ya ba soupapes,ba pompe oyo ezali kotambolatambolampe kokangisa ba raccords na ndambo to koleka.

 

 

What Are the Disadvantages of Evaporative Cooling?Likama ya misato ezali kobotama mingi ya ba micro-organismes mpe ba slime biologiques.Concentration ya likolo-ba solides dissous ezali na ba nutriments riches lokola azote na phosphore, oyo epesaka esika ya bokoli oyo ebongi pona bactérie, ba algues na ba champignons.

 

Ebele ya slime biologique ekangamaka na efelo ya kati ya ba pipelines mpe ya ba remplisseurs, ekangaka ba canaux ya koleka ya mayi mpe ekitisaka volume ya circulation ya mayi ya refroidissement.

 

Slime biologique esalaka mpe couche ya couverture na surface ya métal, esika bokeseni ya concentration ya oxygène ekosala que corrosion localisée na se ya potopoto. Na tango wana kaka, ba micro-organismes eko décomposer ba matières organiques pona kobimisa ba substances acides, eko aggraver lisusu corrosion ya pipeline pe ekosala cycle vicieux ya écaille, slime pe corrosion.

 

 

 

What is an evaporative condenser?

Fonctionnement ya tour ya refroidissement etie motema na blowdown pona ko contrôler TDS na kati ya intervalle ya sécurité. Lolenge moko na moko ya bisaleli ya refroidissement ezali na norme ya contrôle fixe ya TDS selon matériel ya tuyau mpe état ya mosala.

 

 

Ba tours ya refroidissement ouverts ordinaires en acier carbone e contrôler généralement TDS na se ya 1000ppm; ba bobines ya refroidissement oyo ekangami na acier inoxydable esengaka TDS na se ya 600ppm; ba équipements anti-corrosion ya côtier e limitaka TDS na se ya 400ppm pona ko réduire teneur ya chlorure.

 

Tango détecteur ya TDS en ligne emoni que valeur numérique eleki standard, valve automatique ya souffle efungwamaka nakobwaka mayi ya bosoto ya concentration ya likolo-, mpe mayi ya sika ya low-TDS make-up ebakisami mpo na ko diluer mayi oyo ezali ko circuler mpe kokitisa concentration ya TDS mobimba.Ba opérateurs bakobakisa pe ba inhibiteurs ya échelle, ba inhibiteurs ya corrosion pe ba biocides pona ko ralentir ba dangers oyo eyaka na accumulation ya TDS, kasi ba agents chimiques ekoki kaka ko retarder ba risques ya concentration pe ekoki ko réduire fondamentalement TDS te, yango wana soufflage régulière ezali kaka méthode ya contrôle ya moboko.

Hydraulic Oil Cooling Tower

Contrôle ya TDS oyo ebongi te ekomatisa pe ba coûts ya exploitation ya production. Kopanzana ya mopepe mingi mpo na kokitisa TDS ememaka na bobebisi monene ya makoki ya mayi, bomati ya ba frais ya bopetoli mayi mpe bosoto; kozanga kopumbwa ekoki kosala ete mbala na mbala ba écailles mpe ba panne ya corrosion ezala, ematisaka ba pertes ya entretien, remplacement mpe ya arrêt. Yango wana,bolandi ya TDS ya tango ya solo-mpe soufflage proportionnel automatique ekomi ba configurations standard ya ba tours de refroidissement industriel moderne, ko équilibrer consommation ya mayi mpe sécurité ya équipement.

 

Hydraulic Oil Cooling Tower

 

Na mokuse, TDS ezali komonisa bosoto nyonso ya minerais mpe ya biologique oyo epanzani na mai oyo ezali kotambola na tour de refroidissement. Concentration na yango continue oyo euti na évaporation ya mayi ezali mosisa ya ba problèmes ya écaille, corrosion mpe ya slime biologique.

 

 

Desalinated Water Cooling Tower

 

Kokamba na bozindo ya TDS na kati ya molongo ya bokengi ya bokeli na nzela ya bopanzi pe bosalisi ya chimique ya qualité ya mayi ezali fungola ya stable, efficace pemolai-bomoi mosala yaba systèmes nionso ya tour de refroidissement ya polele pe ya kokangama. Kozanga kotala bolandi ya TDS ekosala ete efficacité ya refroidissement ekita, kobebisa bisaleli mbala na mbala mpe ba pertes économiques ya monene mpo na ba lignes ya production industrielle.

null

Tinda mituna .