lnLokota

Kosala hiver tour na yo ya refroidissement: Guide essentiel ya protection ya congelation

Sep 08, 2026

Botika message .

Cold Wave Alert: Essential Winter Protection For Closed Circuit Cooling TowersLokola eleko ya malili ezali kobɛlɛma, bakambi ya bisika oyo ezali na malili bazali kokutana na mokakatano monene: kobatela ba systèmes na bango ya refroidissement industriel na molunge makasi. Mai epanzani tango ekangamaka na congelé, oyo ekoki kosala que ba tuyaux epanzana, ba bobines ya échangeur ya chaleur epanzana, pe ba pompe ebeba-oyo esali que ba réparations efuta mbongo mingi pe ba arrêts eumelaka.

 

Mpo na ekangami-ba tours ya refroidissement ya circuit,kopekisa kobebisama ya congelation ezali kaka te mpo na entretien; ezali mpo na continuité ya mombongo. Tala ba stratégies oyo eleki efficace pona ko winteriser tour na yo ya refroidissement.

 

 

1. Dose ya Glycol (Méthode oyo ekoki kotyelama motema) .

 

Detailed Cooling Process Of Oasis Bingfeng Counterflow Closed-Circuit Cooling TowerKobakisa glycol (mbala mingi propylène to éthylène glycol) na mai oyo ezali kotambola ekitisaka point de congelation na yango. Oyo ezali solution standard pona ba systèmes ya circuit fermé-po fluide ya procédé ezali isolé na atmosphère.

 

 

 

 

Likanisi:Batelá glycol oyo ekoki mpo na kobatela molunge oyo ezali ata 10 degrés F (-12 degrés ) na nse koleka molunge ya nse oyo ekanisamaki na esika oyo ozali.

Komeka:Meka mbala na mbala concentration ya glycol na refractomètre mpo na ko assurer que niveau ekiti te mpo na ba fuites to make{0}}up ya mayi.

 

2. Chauffe-eau électrique & Chauffe-eau ya bassin

 

Complete Analysis Of The Cooling Process in Oasis Bingfeng's Hybrid Flow Dual-Inlet Closed-Circuit Cooling TowerMpo na système ya mayi ya libanda ya pulvérisation (oyo ezali polele na mopepe), mbala mingi glycol esalelamaka te. Na esika na yango, ba chauffe-eau électrique etiemaka na kati ya bassin ya mayi ya malili-.

 

 

 

 

 

 

Mosala:Ba chauffe-eau oyo e activer automatiquement tango température ya mayi ekiti pene ya congelation, e garder fluide ya mayi ya bassin po ba pompes ya pulvérisation ekoka kosala.

Toli:Sala que capacité ya chauffe-eau ezala na taille correcte pona volume ya bassin na yo pe ba conditions ya isolation ya esika.

 

3. Fonctionnement intermittent & Drain Down

 

Working Process Of A Crossflow Closed Circuit Cooling TowerSoki esengeli te ete tour ya refroidissement esalaka 24/7 na eleko ya malili:

Kolongola mai na nse:Kolongola mai mobimba na bassin mpe ba tuyaux nionso soki système ekozala na mosala te na boumeli ya eleko molai. Salelá mopɛpɛ oyo enyatami mpo na kobimisa mai oyo etikali na ba buse ya pulvérisation mpe na ba bobines.

Kokima mbangu na ntango mosusu:Soki charge epesi nzela, tambuisa système na tango na tango mpo mayi ezala kotambola, kasi sala que ba chauffe-eau ya bassin ezala actives na tango ya ba cycles ya off-.

 

4. Insulation mpe Ba Barrières ya Mopepe

 

Working Process Of A Composite Flow, Single Inlet Closed Circuit Cooling TowerMopɛpɛ ya malili ekoki kobakisa mpenza mbangu ya kobungisa molunge mpe likama ya kozala malili.

Botia ba panneaux isolé zinga zinga ya boîtier ya tour.

Salelá biloko oyo epekisaka mopɛpɛ na bisika oyo mopɛpɛ ekɔtaka mpo na kokitisa mopɛpɛ ya malili oyo ekɔtaka na ndako molai nzokande ozali kaka kopesa nzela na mopɛpɛ oyo esengeli mpo na kosala.

 

 

 

Maloba ya nsuka

 

Kozela te mbula ya neige ya liboso mpo na kokanisa kobatela na congelation. Kotala ba éléments chauffants na yo, komeka niveau ya glycol na yo, mpe ko vérifier logique ya contrôle na yo sikoyo ekoki ko sauver yo ba nkoto ya ba dollars na remplacement ya équipement na sima.

Ozali na mposa ya toli mpo na kopona concentration ya glycol oyo ebongi to taille ya chauffe-eau mpo na modèle na yo spécifique? Contactez équipe na biso ya ingénierie lelo.

 

null

Tinda mituna .