lnLokota

Application ya ba Tours de Refroidissement ya Circuit Fermé na ba Centres ya Données

Mar 19, 2026

Botika message .

Foundry Closed Cooling Towers: Adapted for Harsh Conditions, Empowering Efficient Production

 

 

Na fonctionnement ya haute-densité ya ba serveurs, ba centres ya ba données esengaka dissipation ya chaleur stable na mbula mobimba. Na nzela ya matomba na yango lokola circulation fermée, efficacité ya échange ya chaleur ya likolo, bobateli mayi pe économie ya énergie, ba tours ya refroidissement ya circuit fermé ekomi solution ya monene pona ba systèmes ya refroidissement na ba centres de données verts, pe ekoki kosalelama mingi na ba IDC ya minene pe ya moyenne-taille pe ba centres informatiques AI.

 

Closed Cooling Tower For Reaction Kettle

 

Ba tours de refroidissement ya circuit fermé e adopter abobine-based ekangami structure ya échange ya chaleur : mayi ya refroidissement ya température ya likolo oyo ewutaka na salle ya ordinateur ekoti na ba bobines ya acier inoxydable na kati ya tour, mpe mayi ya pulvérisation ya libanda ezipaka ndenge moko ba surfaces ya bobine. Ba ventilateurs ebendaka mopepe mpo na kolongola molunge, ko réaliser mécanisme double ya échange ya chaleur ya "circulation interne mpo na refroidissement mpe circulation extérieure mpo na rejection ya chaleur". Système yango esimbaka ba modes ya fonctionnement misato ya mayele: na été ya température ya likolo-, esalaka elongo na ba chillers pona ko refroidir; na printemps, automne to na température ya butu ya nse, ebalukaka na refroidissement ya ofele mpe epesaka refroidissement directement; na ba saisons transitoires, e adoptaka mode pré-cooling, esika mayi e refroidir liboso na tour ya refroidissement avant ekota na ba chillers, ekitisaka mingi temps ya fonctionnement ya ba unité ya refroidissement.

 

The Ideal Partner For Air Compressor Energy Efficiency And Performance Enhancement: Why Choose The Oasis Bingfeng Closed-Circuit Cooling Tower?

 

Ba avantages na yango ya moboko ezali prominent:Ya liboso, efficacité ya likolo pe économie ya énergie. Efficacité ya échange ya chaleur ekomaka likolo ya 82%, 17% koleka oyo ya ba tours de refroidissement ouvert. Esangisi na contrôle ya fréquence variable, PUE ekoki kokitisa na 1,15–1,25, kokata consommation annuelle ya énergie ya refroidissement na 30%–40%.Ya mibale, bobateli mayi ya monene. Cirulation ya kokangama ekitisaka évaporation mpe perte ya drift, na taux ya économie ya mayi-ya 60%–80%. Centre moko ya ba données ebombaka koleka 26.000 tonnes ya mayi mbula na mbula.Ya misato, kobatela bisaleli. Ezali ko isoler poussière na ba gaz acides, ekitisaka écaille na corrosion, e prolonger vie ya service ya ba bobines na plus de 10 ans, pe ekitisaka ba coûts ya entretien na 35%.Ya minei, stabilité pe fidélité. Fluctuation ya température ya mayi ya sortie ekambami na kati ya ±1 degré , ko adapter na dissipation ya chaleur ya densité ya likolo-ya koleka 30kW na armoire moko pe kokokisa masengi ya ba clusters ya AI.

 

 

 

Hydraulic Oil Cooling Tower

 

Na ba applications pratiques, sima ya ko remplacer na ba tours de refroidissement ya circuit fermé, centre informatique AI na Delta ya ebale Yangtze ebongisaki efficacité na yango ya refroidissement de 62% à 83%, ekitisaki proportion ya consommation ya énergie ya système de 48% à 35%, mpe e économiser plus de 1,2 millions de kWh ya courant na mbula.

 

Centre moko ya ba données ya bord na esika ya sable mpe ya mopepe na ouest ya Chine e adoptaki ba tours de refroidissement fermés FRP, ememaki taux ya corrosion na se ya 0,5% mpe ekati moyenne ya coût annuel ya entretien de 150.000 yuans à 80.000 yuans.

 

Pona boponi ya modèle, esengeli N+1 configuration redundante, na kotalaka température ya ampoule humide-, charge ya refroidissement na etando ya sol, na priorité epesami na ba modèles ya sec-humide double-uti na fréquence variable intelligente.

 

 

 

Na bomati ya densité informatique ya ba centres ya ba données mpe na promotion ya but "dual carbone", ba tours de refroidissement ya circuit fermé ekozala amélioré vers modularisation, intelligence mpe adaptation na refroidissement liquide, ekokoma soutien ya moboko mpo na ba systèmes ya refroidissement na ba centres de données verts.

Tinda mituna .